Home › LG dryer error codes › nP

LG Dryer nP Error

Last reviewed 11 November 2026 · Checked against LG's official support documentation and model manuals
nP
A problem with the electrical wiring in the home — no current is detected at the heater. LG's checks are outlet-and-breaker checks; the outlet itself is checked by a licensed electrician, and a dryer still not heating needs repair service.

Lowercase n, uppercase P — and not PS: nP is about current reaching the heater; PS is about voltage in the cord. LG gives them separate entries.

What to check first

An nP code means, in LG's US wording, there is a problem with the electrical wiring in the home, and no current is being detected at the heater. Its checks stay on the supply side, in a careful order: the cord seated in a grounded outlet matching the 240V rating plate, the breaker switched OFF for at least 10 seconds, and then the boundary LG draws explicitly — the outlet should be checked by a licensed electrician. If the dryer is still not heating after that, LG's endpoint is repair service. There is no parts procedure for nP, because the code is not accusing a part.

Safety first

Common causes

The home wiring / supply side

LG's definition is the cause: the problem is with the electrical wiring in the home. The heater is reporting an absence — no current detected — which is why every published check is about the outlet, the breaker and the cord's seat, and none is about the dryer's internals.

A breaker half-tripped or a poor outlet connection

LG's two user checks target exactly this territory: a grounded outlet that matches the 240V rating plate, and a breaker reset held OFF for at least 10 seconds from the main power supply. A 240V dryer circuit can lose one leg and leave a motor running without heat — the not-heating symptom LG names.

Step-by-step checks

  1. Check the cord and outletMake sure the power cord is plugged securely into a grounded outlet matching the 240V rating plate requirement. (LG US step 1.)
  2. Reset the breaker — OFF for at least 10 secondsTurn the dryer's circuit breaker OFF from the main power supply for a minimum of 10 seconds, then back ON. (LG US/UK.)
  3. Have the outlet checked by a licensed electricianLG's step, with its boundary in its own words: the outlet should be checked by a licensed electrician. This is not a user test with a multimeter unless you are that electrician.
  4. Still not heating? Book repair serviceLG's endpoint: if the unit is still not heating, it will require a repair service.

When to call a technician

Two endpoints, by LG's own split: the outlet goes to a licensed electrician; the dryer (supply proven good, still not heating) goes to repair service. Quote nP exactly, and say which side has already been checked — it saves a duplicated visit.

Model differences

What you haveWhat changes
Gas dryernP is documented on LG's lists in the 240V electric context (heater current, rating plate). A gas dryer's supply codes differ by model — if a gas unit shows nP, the supply-side order (outlet, breaker, electrician) is still LG's pattern, but let the model manual confirm it.
Display reads PS insteadPS is improper voltage within the power cord — terminal-block wiring territory, just-installed machines especially: the PS page.

One-page checklist — nP

Official LG references

Frequently asked questions

Is nP a fault in the dryer or in my house?

LG's US definition answers directly: a problem with the electrical wiring in the home — no current is being detected at the heater. That is why its checks are outlet and breaker checks, why the outlet check belongs to a licensed electrician, and why the dryer only goes to repair service if it still will not heat with the supply proven.

The drum turns but there is no heat. Is that nP's symptom?

It fits LG's endpoint exactly: “if the unit is still not heating, it will require a repair service.” On a 240V circuit the motor and the heater draw differently, so a supply problem can leave one working without the other — work LG's checks in order rather than assuming the heater element first.

nP vs PS — which do I have?

Read the display: nP is no current detected at the heater (wiring in the home); PS is improper voltage within the power cord (cord/terminal-block installation). LG lists them side by side because they split the supply problem in two — the checks differ, so the digit matters.

Related LG dryer codes

PS
Improper voltage in the cord — nP's sibling supply code.
PF
Power failure — the interruption code.
gAS
The gas dryer's supply code — valve and line, not volts.